Specifications
| Specifications | SS | SP | DS | DP |
|---|---|---|---|---|
| Electrical power, W | 250 | 270 | 475 | 475 |
| Rated voltage, V | 48 | 24 | 48 | 24 |
| Rated torque, Nm | 0.22 | 0.22 | 0.22 | 0.22 |
| Peak torque, Nm | 0.7 | 0.7 | 0.7 | 0.7 |
| Rotation speed at ideal idle speed, rpm | 11800 | 13230 | 22920 | 22920 |
| Rated current, A | 6.7 | 14.6 | 12.6 | 25.3 |
| Moment constant, mNm/A | — | — | — | — |
| Moment constant, Nm/A | 0.03 | 0.015 | 0.0173 | 0.0087 |
| Winding resistance phase-to-phase, mOhm | 370 | 92.5 | 123.5 | 31 |
| Winding inductance phase-to-phase, µH | 250 | — | — | — |
| Number of pole pairs, pcs | 7 | 7 | 7 | 7 |
| Efficiency, % | 87 | 87 | >87 | >87 |
| Stator diameter (D), mm | 38 | 38 | 38 | 38 |
| Stator length (L+ Hall sensor), mm | 27 | 27 | 27 | 27 |
| Stator length (L without Hall sensor), mm | 22 | 22 | 22 | 22 |
| Inner diameter of the rotor (d), mm | 18 | 18 | 18 | 18 |
| Rotor length (I), mm | 23 | 23 | 23 | 23 |
| Motor weight, gramm | 66 | 66 | 66 | 66 |
Note:
When ordering, check the current information on the specifications
Designation T – high-torque series
The length of electric motors with the designation T is indicated without Hall sensors
The inductance will be measured after fabrication
* Under development, specifications are planned